12426-4-0104 Page 1INSTALLATION INSTRUCTIONSANDOWNER'S MANUALGRAVITY VENTED DUAL WALL FURNACEMODELGWT-50-2 (SG, RB)EFFECTIVE DATE JANUAR
Page 10 12426-4-0104IMPORTANT — Avoid securing too tightly and disturbing the inner casing. Do not try to force furnace into a wall opening which is
12426-4-0104 Page 11THERMOSTAT LOCATION (SG MODELS)CAUTION — Do not run wire behind ß anges of Header Plate or in any location where it might be
Page 12 12426-4-0104FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a Þ re or explosion may result cau
12426-4-0104 Page 13VENT SAFETY SHUTOFF SYSTEMPROPER MAIN BURNER FLAMEThis appliance must be properly connected to a venting system. This applia
Page 14 12426-4-0104GENERAL All furnaces have been Þ re-tested to check for proper operation. This includes main burner ß ame, pilot ß ame, and ga
12426-4-0104 Page 15 1 WFA-115 HEADER GASKET 2 GWT-175 HEADER ASSEMBLY (INCLUDES NO. 1, GASKET) (USA) 2 15756 HEADER ASSEMBLY (INCLUDES N
Page 16 12426-4-0104PARTS VIEW
12426-4-0104 Page 17No. Number Description 1 GW- 130 Remote Bulb Control Kit 2 R-1224 Remote Bulb Control 3 R-2499 Wire Assembly 4 R-1162 C
Page 18 12426-4-0104 GWTB-2 FOR MODELSGWT-25 (SG, RB), GWT-35 (SG, RB), GWT-50 (SG, RB)OPTIONAL BLOWER INSTALLATION INSTRUCTIONSInstalling Blower Us
12426-4-0104 Page 19 Fan ControlThe automatic fan control is located on the bottom of the blower assembly. The fan control is a nonadjustable, au
Page 2 12426-4-0104SECTION PAGEImportant Safety Information ...
Page 20 12426-4-0104SERVICE NOTESEmpire Comfort Systems, Inc.Nine Eighteen Freeburg Ave.Belleville, Illinois 62220-2623PH: 1-618-233-7420PH: 1-800-8
12426-4-0104 Page 3THIS IS A HEATING APPLIANCEDO NOT OPERATE THIS APPLIANCE WITHOUT OUTER CASING INSTALLED.IMPORTANT SAFETY INFORMATION• DO NOT
Page 4 12426-4-0104Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must Þ nd out if you can sm
12426-4-0104 Page 5IntroductionVented wall furnace is shipped ready to install in a 2" x 4" stud wall, with studs 16" (406mm) cen
Page 6 12426-4-0104Note: No vent equipment supplied with furnace.4" Oval (all parts purchase locally) 1. Type B-1 oval pipe 2. Single story
12426-4-0104 Page 7Check all local codes for requirements, especially for the size and type of gas supply line required.Recommended Gas Pipe Diam
Page 8 12426-4-0104CLEARANCESVENTILATION AND COMBUSTION AIRLOCATION - ALL MODELSROUGH-IN INSTRUCTIONS 1. In selecting a location for installation, i
12426-4-0104 Page 9Figure 2FINISHING INSTRUCTIONSPlastering (Figure 4)In new construction use only plain (not perforated) gypsum lath around furn